Turn on the water supply
Turn on the water supply at the stop valves and inspect all the
connections for any leaks (Ill. 10).
Flow rate adjustment
If flowrate adjustment is necessary because the wash basin is too small or
the water pressure is too high, turn the stop valve(s) clockwise to limit the
flow. Confirmation of wash basin specifications is highly recommended
before installation of the Automatic Faucet.
Temperature adjustment
The water temperature has been factory set at 100°F (38°C, Max: 42°C ±
3°C). Depending on the supply water pressure and other local conditions,
the water temperature may not be kept as specified. In such a case,
adjust the temperature by turning the temperature control handle (Ill. 11).
NOTE: If turning the temperature control handle changes the
temperature opposite of the direction indicated, make sure the hot water
supply is connected to the left inlet bracket.
Adjusting maximum outlet temperature
1. Shut the water off at the stop valves.
2. To decrease temperature:
Remove screw and pull handle slowly to remove. turn handle counter-
clockwise one notch and reinstall onto cartridge.
To increase temperature:
Remove screw and pull handle slowly to remove. turn handle clockwise
one notch and reinstall onto cartridge.
3. Secure handle with screw.
4. Open shut off valve.
5. Check water temperature.
**Repeat steps 1-5 if necessary.
Ill. 10
Open
TESTING AND CALIBRATION
Ill. 11
Temperature Control
Temperature
Handle
Control
Handle
Close
Stop valve
Screw
8
Close
Stop Valve
Open
Hot
HOT
COLD
Cold