Learning procedure
The detector must be learnt by the control unit to transmit the signal if motion is detected. To run the device leaning procedure on
the control unit, proceed as follows.
The detector may be learnt by the control unit only within three minutes from when it is switched on.
1. Insert the batteries into the compartment on the back of the detector.
2. The tamper switch must be open (released).
3. Enable learning mode on the control unit. Within three minutes from switch-on, hold the function button pressed for
10 seconds and then release it when the blue LED blinks once.
4. After having been leant by the control unit, the detector is automatically recorded in the system. Check the control unit to
check that the learning and registration procedure were performed correctly.
5. Once learnt by the control unit, if the detector connection is lost, the LED will blink once every 20 minutes to signal the
fault.
Installation
Surface installation:
1.
Remove the fixing screw and the cover.
2.
Detach the provisions for holes for fastening on a surface
placed on the base.
3.
Using a template for the holes, drill the holes in the surface.
4.
Insert the anchor bolts if the device is fixed to plaster or
bricks.
5.
Screw the base into the anchor bolts.
6.
Screw the cover back onto the base.
Corner installation:
1.
Detach the two provisions for holes on the triangular bracket.
2.
Using the two holes as template, drill the holes corresponding to the
corner surface.
3.
Insert the anchor bolts.
4.
Screw the triangular bracket onto the anchor bolts with the two
position indicators on the top towards the user.
5.
Install the detector on the hooks of the triangular bracket.
6.
If necessary, detach the four provisions for holes for fixing in the
corner.
7.
Use the hole provisions for fixing in the corner as a mask to make the corresponding holes on the surface in
the corner.
8.
Insert the anchor bolts if the device is fixed to plaster or bricks.
9.
Screw the base into the anchor bolts.
10. Screw the cover onto the base and check that the tamper switch is completely compressed against the
triangular bracket.
Hereby, URMET S.p.A. declares that the radio equipment type: INDOOR INFRARED DETECTOR WITH CAMERA IR600VC is
in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet
address: www.elkron.com.
CLICK ON THE FOLLOWING LINK OF THE ELKRON SITE TO ACCESS THE PRODUCT TECHNICAL
SHEET AND DOWNLOAD THE COMPLETE MANUAL:
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and
electronic equipment (WEEE).
The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that this product must not be
disposed of with your other household waste.
Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point
for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at
the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health
and the environment.
For more information about where you can drop off your waste equipment for recycling, please contact your local city office,
your household waste disposal service or the shop where you purchased the product.
SIMPLIFIED EU DECLARATION OF CONFORMITY
ELKRON
Tel. +39 011.3986711 - Fax +39
011.3986703
www.elkron.com
– mail to: info@elkron.it
Hole provisions for fixing
on surface (x 2)
Hole provisions for corner
fixing (x 4)
Triangular bracket for
installation in corners
ELKRON is a trademark of URMET S.p.A.
Via Bologna 188/C – 10154 Turin (TO) Italy
www.urmet.com
MADE IN TAIWAN

Publicité

Table des Matières
loading

Table des Matières