Flame Characteristics; Restricting Vertical Vents - Model Gds60 - Napoleon GDS60-1N Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour GDS60-1N:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

48

10.3 FLAME CHARACTERISTICS

It's important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.
EN

10.4 RESTRICTING VERTICAL VENTS - MODEL GDS60-1

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to "ACCESORIES" in the "REPLACEMENTS" section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating
a more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
W415-1328 / A / 01.05.16
PILOT
ELECTRODE
BURNER
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
54.1B
77.3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Gs60-1nGds60-1pGs60-1p

Table des Matières