7.0 OPTIONAL BLOWER INSTALLATION
Ensure that the access cover plate has been
A.
installed. For location, see "SWITCH AND
BRACKET INSTALLATION" section.
Remove the on/off switch bracket and the
B.
cover plate below it. The switch spacers and
cover plate may now be discarded.
Decide which side of the blower housing you
C.
prefer the on/off switch to be located on.
Remove the top 2 screws from the left outer
D.
edge of the rear appliance panel.
Mount and secure the blower housing using
E.
4 screws (two of which were removed in
previous step). Ensure that the on/off switch
wires pass through the appropriate slot
located on either side of the blower housing.
Remove the 2 screws from the side of the
F.
blower housing that you want the switch to be located on
and re-secure the on/off switch.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 15-30 minutes
after lighting the appliance and will run for approximately
30-45 minutes after the appliance has been turned off.
Use of the fan increases the output of heat.
Drywall dust will penetrate into blower bearings causing
irreparable damage and must be prevented from coming
into contact with the blower or its compartment.
Any damage resulting from this condition is not covered
by the warranty policy.