The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
EN
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location
for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
When the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
The appliance, when installed with a blower, must be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada
or the ANSI/NFPA 70-1996 National Electrical Code in the United States. The blower power cord must be
connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/
HR)
Max. Steady State
Effi ciency (w/the fan
on)
Max. A.F.U.E.
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas
Supply Pressure
Manifold Pressure
(Under Flow
Conditions)
W415-1328 / A / 01.05.16
AND QUALITY!
GDS60-1
NG
0-4,500
35,000 (Top vent)
21, 000 (Rear vent only)
27,300
78%
72%
4.5" (11mb)
Water Column
7" (17mb)
Water Column
3.5" (9mb)
Water Column
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org
LP
0-4500
31,500 (Top vent)
21,000 (Rear vent only)
24,570
78%
71%
11" (27mb)
Water Column
13" (33mb)
Water Column
10" (25mb)
Water Column
4.1B
GS60-1
NG
LP
0-4500
0-4500
35, 000
31,500
27,300
24,570
78%
78%
72%
71%
4.5" (11mb)
11" (27mb)
Water Column
Water Column
7" (17mb)
13" (33mb)
Water Column
Water Column
3.5" (9mb)
10" (25mb)
Water Column
Water Column