Grandeurs D'influence - Chauvin Arnoux C.A 6456 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.5.3
MEASUREMENT PROCEDURE
The measurement is started automatically and is continuous.
4.5.4
MEASUREMENT RESULTS
MEASUREMENT RESULTS
MEASUREMENT RESUL
The measured values and complementary calculated results are described in the table of § 4.1.4
(position
of the switch).
of the switch).
4.5.5
CHARACTERISTICS
4.5.5.1 Measurement ranges and accuracy
Particular reference conditions :
- peak factor = 1.414,
- DC component < 0.1%,
- operating frequency domain = 15.3 to 450Hz.
Characteristics with an MN 20 current probe:
Display range
Specified measurement domain
Accuracy
Note : in measurement of I
, the accuracy is ancreassed by 5%.
SEL
Caractéristiques avec une pince C172 :
Display range
Specified measurement domain
Accuracy

4.5.5.2 Grandeurs d'influence

Influencing
quantities
T
Température
Température
Relative humidity
Power supply voltage
Frequency (without the current probe)
Frequency (without the current probe)
Common mode rejection in
AC 50/60Hz en DC
AC 50/60Hz en DC
www.electronicaembajadores.com
400mA
5.0 - 399.9mA
2% + 10pt
400mA
5.0 - 399.9mA
2% + 10pt
Limits of the domain of
use
-10 to+ 55 °C
1 %/10 °C ± 1pt
1 %/10 °C ± 1pt
10 à 85 % HR at 45°C
1 % / V + 1pt
1 % / V + 1pt
6,8 to 10 V
15.3 to 450Hz
0 to 500 V AC
76
4A
40A
0.400 - 3.999A
4.00 - 20.00A
1,5% + 2pt
1.2%+2pt
4A
40A
0.400 - 3.999A
4.00 - 20.00A
1,5% + 2pt
1,2%+2pt
Variation of the measurement
V
Variation of the measurement
T
Typical
Typical
Maximum
2 %/10 °C + 2pt
2 %/10 °C + 2pt
2 %
2 %
3 % + 2 pt
3 % + 2 pt
2%/ V + 2pt
2%/ V + 2pt
0,5%
0,5%
1%
1%
50dB
50dB
40dB
40dB

Publicité

Table des Matières
loading