7

Technical data

The specifications are typical values at room temperature.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
7.1

Accuracy

Position resolution
Analog
Dependent on evaluation
Digital
BML...-M3_ _-...
1 µm, 2 µm, 5 µm, 10 µm
BML...-M5_ _-...
2 µm, 4 µm, 10 µm, 20 µm
Repeat accuracy
< 1 increment
System accuracy
BML...-M3_ _-...
±10 µm
BML...-M5_ _-...
±20 µm
Hysteresis
BML...-M3_ _-...
≤ 2 µm
BML...-M5_ _-...
≤ 4 µm
Max. non-linearity of
processing electronics
BML...-M3_ _-...
≤ ±2 µm
BML...-M5_ _-...
≤ ±4 µm
7.2

Ambient conditions

Operating temperature
–20°C to +80°C
Storage temperature
–30°C to +85°C
Shock rating
100 g/6 ms
Continuous shock
100 g/2 ms
per EN 60068-2-27
2)
Vibration load
12 g, 10 to 2000 Hz
per EN 60068-2-6
2)
Degree of protection per
IP67
IEC 60529
External magnetic fields
Relative humidity
< 90%, non-condensing
www.balluff.com
1)
< 30 mT (to avoid
permanent damage)
< 1 mT (to avoid influencing
the measurement)
7.3

Supply voltage

Supply voltage
5 V ±5%
3)
Current draw
< 50 mA + controller current
draw (depending on internal
resistance), at 5 V supply
voltage
Reverse polarity
No
protection
Overvoltage protection
No
Dielectric strength (GND
500 V DC
to housing)
7.4

Output

Output signals
See Tab. 4-2 on page 12
Output circuit
RS422 (Line Driver)
7.5

Dimensions, weights

Reading distance
See Tab. 4-1 on page 11
sensor head/magnetic
tape
Maximum movement
20 m/s
speed
(depending on type, see
Tab. 6-1 and Tab. 6-2 on
page 17)
Weight (sensor head)
21 g (without cable)
Material (housing)
Aluminum
Magnetic tape
10.5×10
temperature coefficient
(like steel)
For
: Use in enclosed spaces and up to a height of 2000 m above
1)
sea level.
Individual specifications as per Balluff factory standard
2)
3)
For
: The sensor head must be externally connected via a
limited-energy circuit as defined in UL 61010-1, a low-power source as
defined in UL 60950-1 or a class 2 power supply as defined in UL 1310
or UL 1585.