Step-by-Step
Open - Stop - Close - Stop
(SbS)
Open - Stop - Close - Open *
function
Open - Close - Open - Close
Opening only
* Factory value
9.1.1.2 - Parameter adjustment procedure: SbS input configuration - Flash output configura-
tion - Discharging of Motor 1 and 2 upon closing - Discharging of Motor 1 and 2 upon opening
Before proceeding, check the parameter to be modified in Table 5 and the action to be performed:
01. On the transmitter (Fig. 22) simultaneously press and hold keys T1 and T3 for 5 seconds then
release them.
02. Within 3 seconds from releasing them, perform the action specified in Table 5 to modify the desired
parameter.
Parameters
Value
Open input
Opening (with open-stop sequence) *
configuration
Pedestrian opening (step by step command)
OGI output
OGI *
configuration
Courtesy light
Electric lock
Presence function
Discharging of
No discharge *
Motors 1 and 2
0.1 sec (minimum)
upon
0.2 sec
closing
0.3 sec
0.4 sec (average)
0.5 sec
0.6 sec
0.7 sec (maximum)
Discharging of
No discharge *
Motors 1 and 2
0.1 sec (minimum)
upon
0.2 sec
when gate
0.3 sec
opens
0.4 sec (average)
0.5 sec
0.6 sec
0.7 sec (maximum)
* Factory value
9.1.2 - Presence function
If the LM100 light modules (not supplied) are connected to this output, this function works as follows:
- with gate closed: when an opaque object interrupts the transmission (infrared) of the photocells, the courtesy light switches on for 5 seconds; after 5
seconds, if the transmission is still interrupted, the courtesy light turns on for another 5 seconds; if, on the other hand, the photocell does not detect
any presence, the courtesy light switches off.
- with the gate moving (opening and closing manoeuvre): the courtesy light is always on.
At the end of the opening or closing manoeuvre or with the gate at a standstill, the courtesy light stays on for a further 5 seconds, then goes off and the
gate behaviour resumes when it is closed.
9.1.3 - Verifying the values set for each parameter (using the transmitter memorised in Mode 1)
The adjustment can be made with any transmitter stored in Mode 1 (see par. 9.3.1). If there is no transmitter memorised in Mode 1, it is possible to
memorise one solely for programming purposes then cancelling it (see Paragraph 9.4).
9.1.3.1 - Parameter verification procedure: Pause time - Pedestrian opening - Motor force - Step-by-Step (SbS) function
Before proceeding, check the parameter to be modified in Table 6 and the action to be performed:
01. On the transmitter (Fig. 23) simultaneously press and hold buttons T1 and T2 for 5 seconds then release them.
02. Within 3 seconds from releasing them, perform the action specified in Table 6 to verify the desired parameter.
03. Release the key when the flashing light or the EcsBus led start flashing: count the flashes. In Table 4, check the value corresponding to the number
of flashes.
Parameters
Actions to be performed
Pause time
Press and hold key T1
Pedestrian opening
Press and hold key T2
Motor force
Press and hold key T3
Step-by-Step function
Press and hold key T4
24 – English
TABLE 6
T4
1
2
T4
3
T4
4
T4
TABLE 5
No. of flashes emitted by
Transmitter key to be
the flashing light or the
used
EcsBus led
T1
1
2
T1
1
T2
2
T2
3
T2
4
T2
1
T3
2
T3
T3
3
T3
4
5
T3
6
T3
7
T3
8
T3
T4
1
T4
2
3
T4
4
T4
5
T4
6
T4
T4
7
T4
8
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
22
T1
Actions to be per-
formed
Press T1 once
Press T1 twice
Press T2 once
Press T2 twice
Press T2 three times
Press T2 4 times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times
23
1
T3
2