10.0
With the torch connected, the wire installed and the gas connection made, earth cable to the Negative
output terminal on the front of the unit.
Mode Key -
Press the Mode Key till the MIG/MAG Welding
Screen is viewed on the display.
MIG/MAG Function Setup Key -
Press the Setup Key - 3.1 - in MIG/MAG Mode to
access the parameters' setup screen .
Use the Right Regulation Knob
"Synergy ON" Mode for normal welding.
Use the Mode Key - 1 - to go back to the MIG/
MAG main screen. Refer to paragraph 7 for the
other parameters' setting.
Right Regulation Knob -
Use the Right Regulation Knob to select the
thickness of the material to be welded.
Note: thickness is refered to a fillet welding
Material Key -
Use the Material Key to view the Synergic Welding Curves available on the unit.
Turn the Right Regulation Key - 5 - or press the Material Key - 6.1.2 - to choose the desired Synergic
Curve, suitable to the type of wire and to the gas going to be used for welding; to confirm your choice
simply press the Mode Key - 1 - to go back to the main screen.
Material
GAS
Once a Synergic Curve is selected, Slope, BBT, Inductance, Wire Speed Balance and Material thickness
settings go back to their default values.
Left Regulation Knob -
11.0
TIG AND MIG/MAG SETUPS SAVE & RECALL
Prog Save & Recall Key -
Figure 17
MIG/MAG - SYN ON WELDING
-
1
-
-
to select the
5
-
5
-
6.1.2
-
7.3
Use the Left Regulation Key to balance the wire speed in % (±40%) and increase or
decrease the arc lenght.
-
4
Use the Prog Save & Recall Key to save and recall the parameters
set by the operator (refer to paragraphs 6.0, 6.2, 9.0 and 10.0).
To save the setup proceed as follows:
• Press the PROG Key - 4 -
• Turn the Right Regulation knob - 5 - to choose the program
• To save the program keep the PROG Key pressed, a beep and
To recall a saved program proceed as follows:
• Press the PROG Key - 4 -
• Turn the Right Regulation knob - 5 - to choose the desired
• Press the PROG Key - 4 -, the wording "LOADING" will confirm
1
-
3.1
7.3
number to save in.
a the wording "OK" will confirm the save.
program number.
the program loading.Use the Mode Key - 1 - to go back to the
MIG/MAG main screen.
35
2
6.1.2
Figure 15
Welding Wire Thickness
Figure 16
Program number
3.1
5