3.0 VENTING

3.0 VENTING
EN
EN
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT
(0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM
COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES
FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT
PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS
REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF
EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
THIS APPLIANCE USES A 4" (102mm) EXHAUST / 7" (178mm) AIR INTAKE VENT PIPE SYSTEM.
For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the
minimum vertical vent length can create dif culty in burner start-up and/or carboning. Under extreme vent
con gurations, allow several minutes (5-15) for the  ame to stabilize after ignition. Provide a means for
visually checking the vent connection to the appliance after the appliance is installed. Use a  restop, vent pipe
shield or attic insulation shield when penetrating interior walls,  oor or ceiling.
NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions
provided for the initial installation.
For horizontal runs, both Wolf Steel and Simpon Dura-Vent venting components may have a 0" (0mm) rise per
For horizontal runs, both Wolf Steel and Simpon Dura-Vent venting components may have a 0" (0mm) rise per
foot. For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" (6.4mm) rise
foot. For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" (6.4mm) rise
per foot.
per foot.
All inner exhaust and outer intake vent pipe joints may be sealed using either red high temp silicone sealant or
All inner exhaust and outer intake vent pipe joints may be sealed using either red high temp silicone sealant or
black high temp Mill Pac with the exception of the appliance exhaust ue collar which must be sealed using Mill
black high temp Mill Pac with the exception of the appliance exhaust flue collar which must be sealed using Mill
Pac (not supplied).
Pac (not supplied).
W415-1326 / 05.23.14
W415-1326 / B / 08.23.18
WARNING
!
Refer to the section applicable to your installation.