6.0 OPTIONAL BLOWER INSTALLATION

BLOWER
EN
A.
Cut and remove the tie securing the blower
switch wires to the heat shield.
B.
Connect the white wire coming from below
the appliance to the terminal on the blower.
C.
Connect the black blower wire to the black
wire coming from below the appliance.
D.
Insert the clips on the blower housing into the
cutouts in the rear shield. Push down to lock
the clips into position.
E.
Secure the blower using the screw and lock
washer supplied.
NOTE: Ensure that all the wires are
tucked into the blower switch housing.
SWITCHES
F.
Open the switch housing by removing the top screw.
G.
Install the thermal switch bracket as illustrated, using
2 of the screws supplied. Connect the flagged leads
to the terminals of the thermal switch.
H.
Install the variable speed switch (rheostat) into
the housing with the wires facing up. Secure the
switch to the housing using the pal nut and the
knob supplied.
I.
Connect the male connector on the switch to the
female connector coming from the appliance.
J.
Pilot Indicator Light: Install the batteries as
illustrated. Replace the batteries annually.
NOTE: If replacing the Pilot Indicator Light,
ensure that the red wire lead connects to the red lead of the thermopile and black to white.
K.
Tuck all of the wires into the housing and close. Secure using the screw removed in Step F.