2
Mechanical Installation
Upon Receipt
Please perform the following tasks after receiving the drive:
Inspect the drive for damage. If the drive appears damaged upon receipt, contact
•
your supplier.
Verify receipt of the correct model by checking the information on the nameplate. If
•
you have received the wrong model contact your supplier.
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets
the conditions listed below.
Environment
Installation Area
Ambient Temperature
Humidity
Storage Temperature
Surrounding Area
Altitude
Vibration
Orientation
Conditions
Indoors
-10°C to +40°C (NEMA Type 1)
-10°C to +50°C (Open-Chassis Type)
When using an enclosure panel, install a cooling fan or air con-
ditioner in the area to ensure that the air temperature inside the
enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
95% RH or less and free of condensation
-20°C to +60°C
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
1000 m or less
10 - 20 Hz at 9.8 m/s2, 20 - 55 Hz at 5.9 m/s²
Install the drive vertically to maintain maximum cooling effects.
8