Problem
Sprayer does not run
Motor is hot or there is a fault in the
at all
motor thermal device.
AND
Display shows E = 06
Sprayer does not run
Check voltage supply to the sprayer
at all
(incoming voltage too low for sprayer
AND
operation).
Display shows E = 08
What to Check
217
How to check
8. Use an Ohm meter to check motor for shorts. Connect
(–) meter lead to motor case. Alternate between moving
the (+) meter lead to the red then the black motor wire.
If the measuring instrument is showing continuity, there
is a short-circuit and the motor needs to be replaced. If
there is no continuity, continue to step 9.
Black
9. Connect the motor connector to the socket(s) on
the controller card again. Connect the power cord,
switch on the on/off switch (position ON) and turn the
pressure regulator knob clockwise half a turn. Replace
the controller card if the motor still does not start up.
Allow sprayer to cool. If sprayer runs when cool, cor-
rect cause of over- heating. Keep spraying system in
cooler location with good ventilation. Make sure motor
air intake is not blocked. If sprayer still does not run,
replace motor.
Turn ON/OFF switch OFF and disconnect power to the
sprayer.
Earthing
Red
Yellow
Original instruction