Battery Management; Alarm Scenarios - CDVI SASIC Manuel D'installation

Unité de gestion sas (centrale + pupitre de gestion)
Masquer les pouces Voir aussi pour SASIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
SASIC
Interlocking controller
Total memory reset on the RF receiver
- Press the RF button until the warning light
L1 comes on.
- Release the RF button.
- Press it again until the warning lights L3
and L4 fl ash three times.
The memory on the RF receiver is full
- The memory on the receiver is full after
85 emitter keys have been recorded.
If you try to record any more,
the warning lights L3 and L4 fl ash three
times and the operation fails.
For more information, please refer
to the Remote Transmitter User Guide.

7.4 Battery management

Battery is on charge
- The AC mains are connected and so is
the ADC 12. The battery is on charge.
The battery warning light fl ashes.
Battery is recharged
- The AC mains are connected and so is the
ADC12. The battery has fi nished charging.
The battery warning light is on and steady.
- If the voltage on the battery terminals
exceeds 14V, then there is an overload.
This is indicated by an alarm
and the battery warning light fl ashes.
No power supply
- The battery takes over from the ADC12
supply. If the voltage on the battery
terminals is between 13.5V and 11.5V,
the battery warning light fl ashes.
Battery is weak
- The voltage is below 11.5V,
the SAS shuts down.

7.5 Alarm scenarios

An alarm can trigger for several reasons:
The following 5 reasons are indicated
on the control panel by this warning light
cdvi.com
48
cdvigroup.com
1. Command switch
- Terminal contacts 19 and 20
on the SAS board
2. Tampering detected on the SAS cabinet
- Anti-tamper contact on the SAS board
3. Battery overload
- Voltage measured on the battery
terminals exceeds 14V.
4. The RF remote transmitter
- Channel 4 on the remote transmitter
is used to arm and disarm the alarm.
5. The SAS in "Emergency" mode
- The two doors open automatically
with the alarm signal.
- To cancel the emergency,
press the "RESET EMERGENCY"
push button for 1 second.
The following two sources are reported
individually:
1. Alarm on door 1
- If after opening, door 1 is not closed
properly, the alarm will trigger
after a 15 second interval.
- After a forced entry at door 1, the alarm
will trigger after a 1 second interval.
Add to this the set time delay
on the lock.