INSTALLATION MANUAL
SASIC
Interlocking controller
are all active, it is the emergency command
which is taken into account.
However, as soon as the emergency
command is cancelled, the SAS must check
the status of the other commands.
If the free entrance command is active,
the SAS remains in free entrance mode.
As soon as the free entrance command
This product is delivered with a varistor.
The varistor must be connected directly to the locking system terminals
(electric strikes, electromagnet, or lock) operated by the device. If the device
functions with several locking systems, each one must be fi tted with a varistor.
The varistor limits overload produced by the strike coil, known as self-effect.
If you are using a "Shear Lock" type of electric strike, electromagnet or lock,
we recommend the use of a separate power supply to the one used by the SASIC.

7] SAS MANAGEMENT

7.1 With the control panel

6
7
10
cdvi.com
40
cdvigroup.com
8
9
11
is cancelled and if the lock command is still
active, the SAS remains in locked mode.

7.1.1 Control panel overview

3
1
14
2
15
4
5
12
13
16
17
EN