4-Door contactless smart card unit
Range: Integrated Access Control /
Group Products
4 portes
®
Gamme: Contrôle d'accès intégré
FR
EN
INSTALLATION MANUAL
MANUEL D'INSTALLATION
FRANCAIS
ENGLISH

Publicité

Table des Matières
loading

Sommaire des Matières pour CDVI DGM4D

  • Page 1 FRANCAIS ENGLISH DGM4D KIT DGM4D TDG4D Centrale Mifare 4 portes ® 4-Door contactless smart card unit Range: Integrated Access Control / Gamme: Contrôle d’accès intégré INSTALLATION MANUAL MANUEL D’INSTALLATION Group Products...
  • Page 2: Presentation Du Produit

    INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller Merci pour l’achat de ce produit et pour la confiance que vous accordez à notre entreprise. 1] PRESENTATION DU PRODUIT Conforme Mifare (système ouvert ® à toutes les marques de badges Mifare ®...
  • Page 3: Éléments Fournis

    Vérification de l’installation citées est l’unité DGM4D garantie Une fois l’installation terminée, lors de la mise sous pour fonctionner correctement. tension de la centrale DGM4D, le voyant de la ou des têtes s’allument orange pendant secondes Rappel de câblage...
  • Page 4: Schéma De Raccordements

    - Les connecteurs J1, J2, J4 et J5 ainsi que les connecteurs J7, J8, J10 et J11 ont un câblage indépen- dant. - Il est conseillé de connecter les têtes TDG4 à la centrale DGM4D progressivement de la porte 1 à 4. A] CâBLAGE DE LA CENTRALE DGM4D...
  • Page 5 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller B] TABLEAUX DE CORRESPONDANCE DE LA CENTRALE DGM4D DGM4D Porte de 1 à 4 Bornier Correspondance Contact relais normalement ouvert Commun relais [Relay 1] Contact relais normalement fermé Bouton poussoir...
  • Page 6: Important

    INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller C ] ELECTRICAL WIRING DIAGRAM: EARTH CONNECTION Important : Tx/Rx A Si vous n’êtes pas certain de la qualité de Tx/Rx B votre terre ou si vous ne disposez pas d’un...
  • Page 7 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller E ] SCHÉMA DE RACCORDEMENTS DES BOUTONS POUSSOIRS Les boutons poussoir de sortie sont connectés aux bornes de la centrale sur les connecteurs J2, J5, J8 et J11. Boutons poussoirs...
  • Page 8 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller G ] SCHÉMA DE RACCORDEMENT : RÉSEAU DE CENTRALES Vous pouvez connecter jusqu’à 5 centrale en réseau par l’intermédiaire du BUS RS485. Les centrales sont connectées, comme ci-dessous, avec un cable blindé et torsadé de 120 ohm (Norm EIS-485). la distance à...
  • Page 9 4 fois de suite Mise à la l’heure de la centrale et la centrale reste en phase d’initialisation. - La mise à l’heure de la centrale DGM4D est réalisée Le relais de l’alarme continue d’être activé en usine.
  • Page 10 L’une ou l’autre de ces interventions sont définis par le service-après-vente de CDVI. Le préjudice imputable à CDVI ne saurait en aucun cas dépasser la valeur du produit. La responsabilité de CDVI ne peut être engagée auprès de l’acheteur, installateur, client final ou qui que ce soit, lors de dommages consécutifs à des imperfections ou mauvais fonctionnement du produit.
  • Page 11 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller cdvi.com cdvigroup.com...
  • Page 12: Product Presentation

    Residents passage log. Stand alone system (no PC connection necessary). 5-controller network (manages 20 doors) on one RS485 bus. DGM4D compatible via the PCV123D. Tags can be erased for reprogramming. Wireless programming of resident tags. Information downloadable via TDG4D reader.
  • Page 13: Mounting Kit

    DGM4D controller is turned on, the indicator light for the heads turns orange for 5 seconds then Cabling goes off The DGM4D controller waits for a tag to be Notes : The 2 power cables can be connected presented to the reader head(s).
  • Page 14: Electrical Wiring Diagram

    - We recommend connecting the TDG4 heads to the DGM4 unit by starting with Door 1, then Door 2, Door 3 and finally Door 4. A] DGM4D UNIT WIRING Controller connectors - J2 or J5 or J8 or J11: Read Head...
  • Page 15: Terminal Block

    INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller B] TABLE OF DGM4D CONTROLLER CORRESPONDENCES DGM4D Door 1 to 4 Terminal block Correspondence Relay contact normally open Common relay [Relay 1] Relay contact normally closed Push button Door contact...
  • Page 16 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller C ] ELECTRICAL WIRING DIAGRAM: EARTH CONNECTION Tx/Rx A Important : Tx/Rx B If you are not sure of the quality of your earth or if you do not have an earth wire, connect...
  • Page 17 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller E ] ELECTRICAL WIRING DIAGRAM: PUSH BUTTONS The exit push buttons are connected to the controller terminals at connectors J2, J5, J8 and J11. Push Buttons Ground J2 ou J5...
  • Page 18 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller G ] ELECTRICAL WIRING DIAGRAM: NETWORKED CONTROLLERS You can connect up to 5 controllers on the same RS485 bus so they function in network. They are connected as shown below, with one 120 ohm shielded twisted pair (Norm EIS-485). Each controller must be minimum 2 meters from another controller and at maximum total length 1 kilometre.
  • Page 19 Setting the controller time in a row and the controller stays in the initialisation - The time on the DGM4D controller was set in the phase. The alarm relay continues to activate and factory, so you can use your smart access control deactivate 4 times in a row as long as the DGM4D controller immediately without having to configure it.
  • Page 20 “Limited Lifetime Warranty”, complete the enclosed registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive remedy.
  • Page 21 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller cdvi.com cdvigroup.com...
  • Page 22 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller cdvi.com cdvigroup.com...
  • Page 23 INSTALLATION MANUAL DGM4D Smart Card Access Control 4 door controller cdvi.com cdvigroup.com...
  • Page 24 Reference : G0301FR0432V02 Extranet : EXE-CDVI_IM DGM4D CMYK A5 EN-FR 02 Creator of electronic access solutions *G0301FR0432V02* CDVI Group FRANCE (Headquarter/Siège social) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDVI CDVI CDVI CDVI UK...