Page 3
OUT1 GREEN LED OUT3 the Foam seal OUT2 RED LED OUT4 6] WIRING CONNECTION TO A DOOR CONTROLLER (INTBUSW) SOLARKPW - SOLARKPB INTBUSW R V B D1D0 H - + 12VDC Buzzer command input Data 0 Data 1 Clock Green LED Red LED 7] LED &...
Page 4
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® 8] 26-BIT WIEGAND FORMAT Chronograms 0 logic 1 logic \DATA1 \CLOCK \DATA0 µS µS Interface - The output format is 26-bit Wiegand (Signals: DATA1, DATA0 and CLOCK), - Output signal in open collectors (pull up of 2.2K in +5V) 26-bit hexadecimal output format.
Page 5
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® 9] 30-BIT WIEGAND FORMAT Signals output in open collectors with pull up in 30-bit hexadecimal format. The output format from the proximity reader is 30-bit wiegand (Signal: DATA1, DATA0 and CLOCK) and is structured as follow: - Parity 1: 1 bit –...
Page 6
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® 11] ARK 8 BITS OUTPUT FORMAT Keypad input Hexadecimal Binary Datas 11110000 11100001 11010010 11000011 10110100 10100101 10010110 10000111 01111000 01101001 ou A 01011010 ou B 01001011 12] LED CONFIGURATION ON CENTAUR SYSTEM...
Page 7
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® 13] LED CONFIGURATION ON ATRIUM SYSTEM* LED ACTUATION GREEN ACCESS ALLOWED / RED ACCESS DENIED / BLUE STAND-BY 14] NOTES cdvigroup.com...
Page 8
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® 15] PROGRAMMING CHART Default values Audible Signal - Illumination duration: 10 seconds - 1 short beep > keypad powered (in standard mode), and key presses, - User code lenght: 5 digits, - 1 long beep >...
Page 9
INSTALLATION MANUAL SOLARKPW-SOLARKPB Dual Technology Digicode /Proximity reader - Wiegand ® Code Length - The user code must be in 4, 5, 6, 7 or 8 digits, Enter the master code - In direct mode, all the keypad keys can be...
Page 10
-25°C à +70°C Certification CE part 15 compliance 2] RAPPELS ET RECOMMANDATIONS Programmation de la double sécurité Montage MODE Afin d’optimiser la fixation du SOLARKPW-SOLARKPB et de prévenir les tentatives d’arrachage, SYSTEME DIGICODE PROXIMITÉ DOUBLE TECHNOLOGIE privilégiez les surfaces planes.
Page 11
VOYANT VERT OUT3 d’étanchéité OUT2 VOYANT ROUGE OUT4 6] RACCORDEMENTS CONNEXION AVEC CONTRÔLEUR DE PORTE (INTBUSW) SOLARKPW - SOLARKPB INTBUSW R V B D1D0 H - + Alimentation 12V DC Alimentation 0V Commande du buzzer Data 0 Data 1...
Page 12
INSTALLATION MANUAL SOLARKPW-SOLARKPB Lecteur double Technologie Proximité/Digicode - Wiegand ® 8] FORMAT DE SORTIE WIEGAND 26 BITS Chronogrammes 0 LOGIQUE 1 LOGIQUE \DATA1 \CLOCK \DATA0 µS µS Interfaçage - La communication s’effectue par une liaison de type Wiegand 26 bits (Format 26 bits hexadécimal).
Page 13
INSTALLATION MANUAL SOLARKPW-SOLARKPB Lecteur double Technologie Proximité/Digicode - Wiegand ® 9] FORMAT DE SORTIE WIEGAND 30 BITS Structure et description du message - Format 30 bits hexadécimal. - La communication s’effectue par une liaison de type Wiegand 30 bits ( Signaux: DATA1 et DATA0 ) La trame est constituée d’une totalité...
Page 14
INSTALLATION MANUAL SOLARKPW-SOLARKPB Lecteur double Technologie Proximité/Digicode - Wiegand ® 11] FORMAT DE SORTIE ARK 8 BITS Entrée clavier Hexadécimal Données binaires 11110000 11100001 11010010 11000011 10110100 10100101 10010110 10000111 01111000 01101001 ou A 01011010 ou B 01001011 12] PARAMÉTRAGE DES VOYANTS SUR LE SYSTÈME CENTAUR ÉTAT VOYANTS :...
Page 15
INSTALLATION MANUAL SOLARKPW-SOLARKPB Lecteur double Technologie Proximité/Digicode - Wiegand ® 13] PARAMÉTRAGE DES VOYANTS SUR LE SYSTÈME ATRIUM* ÉTAT VOYANTS VERT ACCÈS AUTORISÉ / ROUGE ACCÈS REFUSÉ / BLEU EN ATTENTE 14] NOTES cdvigroup.com...
Page 16
INSTALLATION MANUAL SOLARKPW-SOLARKPB Lecteur double Technologie Proximité/Digicode - Wiegand ® 15] PROGRAMMATION Valeurs par défaut - 1 bip court > Mise sous tension et bip touche. - Tempo éclairage : 10 s (En mode standard). - 1 bip long > Validation d’une saisie - Nombre de termes : 5.