CDVI SASIC Manuel D'installation page 41

Unité de gestion sas (centrale + pupitre de gestion)
Masquer les pouces Voir aussi pour SASIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
SASIC
Interlocking controller
General alarm warning
1
light
Warning light and Open
2
doors 1 & 2 Push Button
3
Master warning light "M"
Button "M/S"
4
Master / Slave
5
Slave warning light "S"
Warning light and Manual
6
door 1 PB
Warning light and Auto
7
door 1 PB
Alarm warning
8
light door 1
Call warning light on
9
door 1
Warning light and PB lock
10
door 1
Warning light and Open
11
door 1 PB
Warning light and Manual
12
door 2 PB
Warning light and Auto
13
door 2 PB
14
Alarm warning light door 2 Door 2 has not closed after timed opening period has expired.
Call warning light on
15
door 2
Warning light and Open
16
door 2 PB
Warning light and Lock
17
door 2
Push Button
*See functioning on chapter 7.1.3
Description of warning lights and commands
Problem detected on the SAS central unit, see alarm scenarios to identify
the reason for the problem.
Requests the opening of the two doors simultaneously for 10 seconds.
If one of the doors is already open or locked, the request to open is cancelled.
If this warning light is lit up and steady, the Control panel is master.
For requests to take over as master or to pass control back and return to slave
status.
If this warning light is lit up and steady, the Control panel is slave.
Transfers the door 1 to manual mode*
Transfers the door 1 to automatic mode*
Door 1 has not closed after timed opening period has expired.
Door 1 is in manual or locked mode and somebody is requesting entrance
at this door using the traffi c light indicator.
Door 1 can no longer be opened using the push button, the traffi c light indicator
or the open commands on the control panels. But it can be opened by an external
reader or by a remote transmitter.
The control panels command the timed door opening on door 1.
Transfers door 2 to manual mode*
Transfers door 2 to automatic mode*
Door 2 is in manual or locked mode and somebody is requesting entrance
at this door using the traffi c light indicator.
The control panels command the timed door opening on door 2.
Door 2 can no longer be opened using the push button, the traffi c light indicator
or the open commands on the control panels. But it can be opened by an external
reader or by a remote transmitter.