6-2. Fuse F1

1
Tools Needed:
3/8 in.

6-3. Short Circuit Shutdown

When contact tip is shorted and sticks to workpiece, the unit output falls to a safe operating level. To resume operation,
release gun trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged.
Turn On unit to continue operation.
2
Turn
Pull Out And Replace Fuse
(Install Flat End Of Fuse Into Cover)
!
Disconnect input power be-
fore opening rear access
door.
1
Fuse Holder Cover
2
Fuse F1 (See Parts List For
Rating)
Fuse F1 protects control transform-
er from overload. If F1 opens, weld
output and fan motor stops. Re-
place F1.
Close and secure access door.
Turn
Ref. 800 101-C
OM-2241 Page 23