7.1
Your Emerson Ceiling Fan/Light Control consists of wall
mounted transmitter and a receiver located inside the
motor assembly. The control is designed to remotely
operate your ceiling fan speed, light intensity and
direction of rotation.
Code switches in the transmitter may be set in
32 different positions. If your fan and light turn on
and off without using your control, you may be
getting interference from other remote units such as
garage door openers, car alarms or security systems.
To remedy this situations, simply change the code
switches in your transmitter per the instructions of
Section 7.3.
7.3
Your Wall Control has Code Switches which must
be set in one of 32 possible code combinations
(Figure 33). The Five Levers (numbered 1, 2, 3, 4,
and 5) on the Switches are factory-set in the ON (up)
position. Change the Switch settings as follows:
Slide the Five Switch Levers in the Wall Control to your
choice of ON (up) or down positions. Use a ball-point
pen or small screwdriver and slide the Levers firmly up
or down.
The Sixth Switch marked ON and I is for Dimming
Control of Lights: Set Switch to ON to allow for
Dimming of the Lights.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
CAUTION
!
To reduce the risk of electrical shock, disconnect the
electrical supply circuit before installing the fan, light
kit or receiver.
7. Wall Control Installation
7.2
Preset Memory Feature: Your Emerson receiver is
equipped with a preset memory feature. If the AC
supply to the receiver is powered OFF through a wall
switch, the control will remember the light intensity and
fan speed. When the switch is turned back ON the light
and fan will resume operation as they were prior to the
switch being turned OFF.
NOTE: Make all wiring connections using
Wire Connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
7.4
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to install
the Ceiling Fan Wall Control into the Outlet Box.
21
21
WALL CONTROL
CODE SWITCHES
1 - 5
ON
1
2
3
4 5
I
DIMMING
SWITCH
I
CODE
SWITCHES
WALL
CONTROL
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF575