7. Wall Control Installation
3-WAY INSTALLATION
(One fan controlled by two different wall controls)
(See Figures 37 and 38).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
7.7
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or fuse box before attempting to install
the Ceiling Fan Wall Control into the Outlet Box.
At all Wall Box locations remove Faceplates and
Screws from existing Controls. Pull Controls out from
Wall Boxes and determine which Wall Box contains
the "Hot" Wire and which Wall Box contains the "Load"
Wire. Also, identify Traveler Wires which are common
to both Wall Boxes. Disconnect Wires from existing
Controls only.
Do not attempt to disconnect any Wires not already
connected to existing Controls.
Before installing the Wall Control, place the Wall Control
in "OFF" mode by pushing "ON/OFF" switch to the
"OFF" position.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
(Continued)
HOT
BLK
SW605
FAN/LIGHT
WALL
CONTROL
TRAVELER
WIRE
NEUTRAL
RECEIVER LOCATED IN THE
CEILING COVER OF THE CEILING FAN
Figure 37
Install the first Wall Control in the Wall Box containing
the "Hot" Wire. Connect the Wall Control Black Wire
with the Yellow Label marked "To Power Supply" to the
"Hot" Wire in the Wall Box. Securely connect the Wires
with the Wire Connector (supplied) (Figure 37).
Connect the Wall Control Black Wire with the Blue
Label marked "To Fan" to the Traveler Wire in the
Wall Box. Securely connect the Wires with the Wire
Connector (supplied) (Figure 37).
Connect the Green Ground Wire to the Bare Copper
Wire or Green Ground Wire in the Wall Box Securely
connect Wires with Wire Connector (supplied)
(Figure 37).
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
24
24
LOAD
BLACK
GROUND
WARNING
ETL Model No.: CF575