SINGLE-POLE INSTALLATION
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all connections
are tight, including ground, and that no bare wire is
visible at the wire connectors, except for the ground
wire.
9.1
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install the
9.2
ceiling fan SW605 wall control into the outlet box.
Remove faceplate and screws from existing wall control.
Pull control out from the wall box. Determine the "hot" wire
and the "load" wire and disconnect these wires from control
(Figure 32). Do not attempt to disconnect any wires not
already connected to existing control.

9. Wall Control Installation

!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse or circuit breaker box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
HOT
BLK
NEUTRAL
RECEIVER LOCATED WITHIN
THE MOTOR HOUSING
Figure 32
20
WARNING
EXISTING
WALL CONTROL
BLACK
GROUND
ETL Model No.: CF965