FOR YOUR OWN SAFETY TURN OFF POWER AT MAIN FUSE BOX OR CIRCUIT BREAKER PANEL BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
1. Fuse or Circuit Breaker blown.
2. Loose power line connections to the Fan.
3. Reverse Switch in Neutral position.
2. Fan sounds
1. Blades not attached to Fan.
noisy.
2. Screws securing Fan Blades to
Motor are loose.
3. Loose Screws in Motor Housing.
3. Fan wobbles
1. Set Screws in Motor Coupler are not
tightened securely.
excessively.
2. Set Screw in the Hanger Ball/Downrod
Assembly is loose.
3. Screws securing Fan Blades to Motor
are loose.
4. Fan Blades are not seated properly.
5. Hanger Bracket and/or Ceiling Outlet Box
is not securely fastened.
6. Fan Blades out of balance.
4. Light fixture will
1. Loose Electrical Connectors.
not illuminate.
2. Remote Control Battery is weak.

13. Troubleshooting

WARNING
!
PROBABLE CAUSE
1. Check Main and Branch Circuit Fuses or Circuit Breakers.
Make sure main power is turned OFF.
2. Check line power connections to Fan.
3. Make sure Reverse Switch position is all the way to one
side.
1. Attach Blades to Fan before operating.
2. Check to make sure the Screws which attach the Blades
to the Motor are tight.
Make sure main power is turned OFF.
3. Check to make sure all Screws in Motor Housing are
snug (Not Over-Tight).
1. Raise Coupler Cover and tighten Set Screws securely.
2. Tighten the Setscrew in the Hanger Ball/Downrod
Assembly.
3. Check to be sure Screws which attach the Fan Blades
to the Motor are tight.
4. Check to be sure that the Screws securing the Fan
Blades seat firmly.
5. Tighten the Hanger Bracket Screws to the Outlet Box,
and/or secure Outlet Box.
6. Interchanging an adjacent (side by-side) Blade pair can
redistribute the weight and result in smoother operation.
Or use supplied Balancing Kit to balance Blades.
1. Shut off the Branch Circuit Electricity at the Main Fuse
Box or Circuit Breaker Panel and check the Receiver
Electrical Connectors for proper installation.
2. Replace the AAA Remote Control Batteries.
Please contact 1-800-777-4440 for further assistance