FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1 . Fuse or Circuit Breaker blown .
2 . Loose Power Line Connections to the Fan .
3 . Reverse Switch in Neutral position .
2. Fan sounds
1 . Blades not attached to Fan .
noisy.
2 . Screws securing Fan Blades to Motor are
loose .
3 . Loose Screws in Motor Housing .
4 . Wire connectors inside switch housing
rattling .
5 . Motor noise caused by solid-state variable
speed controls .
6 . Screws holding blades to flanges are loose .
3. Fan wobbles
1 . Set Screws in Motor Coupler are not
excessively.
tightened securely .
2 . Set Screw in the Hanger Ball/Downrod
Assembly is loose .
3 . Screws securing Fan Blades to Motor
are loose .
4 . Fan Blades are not seated properly .
5 . Hanger Bracket and/or Ceiling Outlet Box
is not securely fastened .
6 . Fan Blades out of balance .
4. LED Light fixture 1 . Loose Electrical Connectors .
will not
illuminate.

14. Troubleshooting

!
PROBABLE CAUSE
WARNING
SUGGESTED REMEDY
1 . Check Main and Branch Circuit Fuses or Circuit Breakers .
Make sure main power is turned OFF.
2 . Check Line power connections to Fan .
3 . Make sure Reverse Switch position is all the way to one
side .
1 . Attach Blades to Fan before operating .
2 . Check to make sure the Screws which attach the Blades
to the Motor are tight .
Make sure main power is turned OFF.
3 . Check to make sure all Screws in Motor Housing are .
snug (Not Over-Tight) .
4 . Check to make sure wire connectors in switch housing are
not rattling against each other or against the interior wall
of the switch housing .
5 . Some fan motors are sensitive to signals from solid-state
variable speed control . If solid-state control is used and
motor noise results, choose an alternative control method .
6 . Tighten screws securely .
1 . Raise Coupler Cover and tighten Set Screws securely .
2 . Tighten the Set Screw in the Hanger Ball/Downrod
Assembly .
3 . Check to be sure Screws which attach the Fan Blades
to the Motor are tight .
4 . Check to be sure that the Screws securing the Fan
Blades seat firmly .
5 . Tighten the Hanger Bracket Screws to the Outlet Box,
and/or secure Outlet Box .
6 . Interchanging an adjacent (side by-side) Blade pair can
redistribute the weight and result in smoother operation .
Or use supplied Balancing Kit to balance Blades .
1 . Shut off the Branch Circuit Electricity at the Fuse Box or