PROline Prosonic Flow 93 FOUNDATION Fieldbus
!
Endress+Hauser
The table below contains the values that are identical for all versions, irrespective of the
type code.
Transmitter Prosonic Flow 93
Teminals
1
L (+)
Power supply ➀
Designation
Functional
AC: U = 85...260 V
values
or
AC: U = 20...55 V
or
DC: U = 16...62 V
Power consumption:
15 VA / 15 W
Intrinsically
no
safe circuit
U
=
260 V AC
m
Input/output circuit
➁ = Bus cable (FOUNDATION Fieldbus)
Fig. 3:
A = View A
Note:
The table below contains the values which depend on the type code (type of device).
Always remember to compare the type code in the table with the code on the nameplate
of your device.
Tansmitter Prosonic Flow 93***-***********G
Terminals
20
+
Designation
Functional
values
Intrinsically
safe circuit
U
=
i
I
=
i
P
=
i
L
=
i
C
=
i
2
3
N (–)
Protective earth
Caution:
Follow ground
network requirements
for the facility
21
22
23
+
<
24
25
26
+
+
FOUNDATION
Fieldbus ➁
U
= 9...32 V DC
B
I
= 12 mA
B
EEx ia
30 V DC
500 mA
5.5 W
10 µH
5 nF
27
7