PROGRAMMING AND STARTUP
SW2 functions
Functions during programming
(DIP1=ON)
DIP2=ON: total open/close programming (see
page 56)
DIP3=ON: pedestrian open/close programming (see
page 57)
DIP4=ON: total opening radio code programming (see
page 55)
DIP6=ON: pedestrian opening radio code
programming (see page 55)
54
Installation Manual
Functions during use (DIP1=OFF)
DIP2: advance warning
DIP2=ON: the flashing light comes on and the
operation begins after a 3 second warning.
DIP2=OFF: the flashing light comes on and the
operation begins immediately.
DIP3: step-by-step or collective opening
DIP3=ON: step-by-step opening (the panel obeys
the key commands during opening).
DIP3=OFF: collective opening (the panel does
not obey the key commands during opening).
DIP4: automatic or step-by-step closing mode (in
total and pedestrian operation)
DIP4=ON: automatic mode (the gate closes
automatically after the standby time has passed,
which is adjusted using T.E.).
DIP4=OFF: step-by-step mode (the gate only
closes when receiving the key command).
DIP5: automatic mode optional (only if DIP4=ON)
DIP5=ON: during standby, the gate obeys the
key commands (this can be closed before standby
time finishes).
DIP5=OFF: the gate cannot be closed until
standby time finishes.
DIP6: no function
Place always in OFF
DIP7: encoder activation
DIP7=ON: encoder enabled
DIP7=OFF: encoder disabled
DIP8: slow down function
DIP8=ON: the gate reduces its speed before
reaching the stopper.
DIP8=OFF: the gate reaches the stopper at high
speed.
DIP9: limit switches configuration
DIP9=ON: gate which opens to the right
DIP9=OFF: gate which opens to the left
DIP10: Type of slowdown (only if DIP8=ON)
DIP10=ON:
progressive
(deceleration ramp 1.5 seconds)
DIP10=OFF: Sudden deceleration
deceleration