Wiring/Configuration-NEMA 4
SubDrive300
To operate a different pump size, a Configuration Switch (SW1) must be positioned to select the correct pump rating .
Reference the chart below for appropriate Configuration Switch setting .
From Power Source
L1
L2
(Input)
Power Supply
From Circuit Breaker
Feed the 230 V power leads through
the large enclosure opening and
securely attach to the terminals
4
marked L1, GND and L2.
3
2
1
4
4
3
3
(default)
2
2
1
1
4
4
3
3
2
2
1
1
4
3
2
4
1
3
2
4
3
2
10
Configuration Switch SW1
See chart below for appropriate controller
setting. Reference the SubDrive/MonoDrive
Installation Manual or inside of lid for
more information.
PRESSURE
SENSOR
SHUT-OFF
Feed the pressure sensor wires
through the small enclosure opening
and securely attach to the sensor terminals.
Configuration Switch SW1
SubDrive300
3 hp (pump)
SubDrive300
5 hp (pump)
#3 Switch
Underload sensitivity selection
OFF Position - Normal(default)
See SubDrive/MonoDrive Installation Manual for more information .
#4 Switch
Steady Flow - Control selection
OFF Position - Standard
See SubDrive/MonoDrive Installation Manual for more information .
Pressure sensor cable connection
Make sure the connection is securely made
PRESSURE
SENSOR
SHUT-OFF
Output to Motor
Red Yel Blk
(Brn) (Blue) (Blk)
(Output)
Feed the motor leads through
the large enclosure opening and
securely attach to the terminals
matching the lead colors to the
colors shown.
ON Position - Low
ON Position - Steady Flow (default)
INT
NO
NO
FAN
RELAY
COM
PFC
INV
FAN
FAN
Sensor Connection
PRESSURE
PRESSURE
SHUT-OFF
SENSOR
Red
Blk
Wh
Grn