OFFSET ADJUST:
Used to adjust the home position of pan / tilt and zoom so all units are perfectly aligned:
 If you're not already in the setup menu, just press the MENU button shortly to enter the setup menu
 Now press the ENTER button for at least 5 seconds to go into offset mode.
 Use DOWN / UP buttons to select one of the available options.
 Press the ENTER button, the display shows the actual offset value.
 Use DOWN / UP buttons to adjust the offset values
 Press the ENTER button to confirm your setting or press the
MENU button to leave without saving the value.
To return to normal working mode: press the MENU button.

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable (number 3 on the picture) that can hold 12 times the weight of the
device when installing the unit. This secondary safety attachment should be installed in a way that no part
of the installation can drop more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Every time you turn the unit on, it will show a welcome message on the display and move all the motors to
their 'home' position and you may hear some noises for about 20 seconds. After that the unit will be ready to
receive DMX signal or run the built-in programs.
Electrical installation for several units on a DMX line:
The DMX-protocol is a widely used high speed signal to control intelligent light equipment.
You need to "daisy chain" your DMX controller and all the connected light effects with a
good quality XLR M/F balanced cable. To prevent strange behavior of the light effects, due
to interferences, you must use a 90Ω to 120Ω terminator at the end of the chain. Never use
Y-cables to split the DMX-line, instead use a good quality DMX splitter!
BRITEQ
®
8/73
OPERATION MANUAL
Pan
-128 ~ 127
Tilt
-128 ~ 127
Zoom
0 ~ 255
BT-W12L10 ZOOM