Flotec INTELLIPUMP FP0S1775A Notice D'utilisation page 4

Masquer les pouces Voir aussi pour INTELLIPUMP FP0S1775A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Repair Parts / Troubleshooting
Anti-Airlock
Hole
Troubleshooting
Risk of electric shock and sudden start. Can shock, burn or kill and can cause electrical shock and per-
sonal injury. Disconnect electrical power to pump before attempting to troubleshoot or work on it.
Symptom
Pump won't start or run from main
switch on property
Pump operates but delivers little or
no water
For parts or assistance, call Flotec Customer Service at
5
4
3
2
1
5125 0905
Possible Cause(s)
Blown fuse
Low line
Defective motor
Impeller
Low line voltage
Something caught in impeller
Small diameter garden hose or long discharge line
Check valve installed without vent hole
AIr lock
Coils or bends in hose
REPAIR PARTS
Ref
Descriptopn
1
Screen
2
Shield
3
Impeller
4
Motor
5
Power Cord
Garden Hose Adapter
NOTICE
To purchase a check valve, call Customer Service at
800-365-6832 and order part number PW73-63.
** If motor fails, replace entire pump. • Not Illustrated.
Orient Part Number with
Anti-Airlock Hole as shown
Tighten 1st
2nd
3rd
Assemble Screen and Shield as shown.
Corrective Action
If blown, replace with fuse of proper size.
If voltage under recommended minimum, check size of wiring. If
OK, contact power company.
Replace pump.
Remove screen, locate source of binding.
Use only 14 gauge or larger extension cords. Use short extension
cords when necessary.
Clean out impeller.
Use larger diameter garden hose or 1" flexible pipe. Eliminate any
excess hose. Short hoses work best.
Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump
discharge & check valve.
Turn off pump for a few seconds, clean out anti-airlock hole and
restart pump.
Straighten hose.
800-365-6832
4
Qty.
Part No
1
PS8-6P
1
PS70-3P
1
PS5-25P
1
**
1
PS117-51-TSU
1
FT0013-43
Anti-Airlock
Hole
5124 0905