Adjusting Window Treatment Settings

Setting Limits
Note: Entering Limit Setup mode
may cause window treatments to
move approximately 203.2 mm
(8 in.)up or down. Be sure that
each window treatment is
positioned so that the fabric can
safely move 203.2 mm (8 in.) up
or down before entering Limit
Setup mode.
1. On any shade column,
press and hold
simultaneously the top
and raise buttons. The
LEDs next to the top
and bottom buttons will
cycle.
Note: At any time while
in Limit Setup mode,
you can move all
window treatments
together to their current
open limit by double-
tapping the top button,
or to their current close
limit by double-tapping
the bottom button.
Note: Once EDUs (electronic drive units
of the window treatment) have been
assigned to shade columns, limits can be
set for an EDU only using the shade
column it is assigned to, and a shade
column can set limits only for those EDUs
assigned to it.
R
2.Select the EDU you want to to adjust
using the top button on the shade
column. Each time you press and release
the top button, a different EDU that is
assigned to that shade column will open
and close in an 203.2 mm (8 in.) range to
indicate it is selected. Press the top
button until the EDU for the window
treatment you wish to adjust moves. (You
can also use the bottom button, which
moves through the assigned EDUs in the
opposite order.)
3. Adjust the currently selected
EDU to the desired level for
the open limit (the maximum
the window treatment is
allowed to open) using the
raise and lower buttons.
4.Press and hold the top button on the
shade column for 5 seconds to store the
current position as the open limit. The
LED next to the top button will flash
quickly for 2 seconds.
5.Adjust the currently selected EDU to the
desired level for the close limit (the
maximum the window treatment is
allowed to close) using the raise and
lower buttons.
6.Press and hold the bottom button on the
shade column for 5 seconds to store the
current position as the close limit.The
LED next to the bottom button will flash
quickly for 2 seconds.
7.Repeat steps 2 through 6 to set the open
and close limits for each window
treatment assigned to the shade column.
8.Press and hold simultaneously the top
and raise buttons on the shade column to
exit Limit Setup mode.