Les langues disponibles

Possible charging programmes
6 Volt mode
Charging programme for 6 V batteries, 1.2 Ah to 120 Ah, temperatures above 0°C
Charge current:
Charge voltage:
6 Volt winter mode
Charging programme for 6 V batteries, 1.2 Ah to 120 Ah, temperature below 0°C
Charge current:
Charge voltage:
Motorbike mode
Charging programme for 12 V batteries from 1.2 Ah to 120 Ah, temperatures above 0°C
Charge current:
Charge voltage:
Motorbike winter mode
Charging programme for 12 V batteries from 1.2 Ah to 120 Ah, temperatures below 0°C
Charge current:
Charge voltage:
Car mode
Charging programme for 12 V batteries from 14 Ah to 200 Ah, temperatures above 0°C
Charge current:
Charge voltage:
Car winter mode
Charging programme for 12 V batteries from 14 Ah to 180 Ah, temperatures below 0°C
Charge current:
Charge voltage:
Battery maintenance charge mode
As soon as the battery is fully charged, the charger switches automatically over to battery
maintenance charge mode. This is indicated appropriately on the display.
Error messages
No battery connected, battery incorrectly connected, battery voltage does not match the
set charging programme. Connect the battery correctly, select the appropriate charging
programme.
The battery voltage 4 minutes after the start of charging is less than 11 V, the battery was
not fully charged after 24 hours of charging time, the battery voltage drops 2 minutes after
end of charging to below 12 V. The battery is defective.
Overheating of the charger. Pull the plug, disconnect the battery from the charger and allow
the charger to cool down.
12
4 A maximum
7.2 V
4 A maximum
7.4 V
4 A maximum
14.3 V
4 A maximum
14.8 V
8 A maximum
14.6 V
8 A maximum
14.8 V