EN
4. The control panel replies with SMS
Change zone name successfully.
Note:
If the input format or content is incorrect, the control panel will send out an SMS to
notice the wrong input.
The first connected sensor is regarded as zone 1; the second connected sensor is regarded as
zone 2, and so on.
The zone name can be 30 characters at most for each line. If the character limit is exceeded,
the control panel replies an notice SMS to your smart phone.
Control Panel Settings
This is to set control panel.
1. Send "8"
2. The control panel replies with SMS
Siren volume(0.mute,1.low,2.high):
1
Siren ringing time(1-9min):
5
Exit delay time(0-299s):
0
Entrance delay time(5-299s):
5
Timed arm/disarm(0.off 1.on,00:00 0 - 00:00 0):
00:00 0 - 00:00 0
17
X330-UM-EN-FR-ES-PT-V1.0.indd 17-18
8
Timing repeat: 1, 2, 3, 4, 5, 6, 7
Door chime(0.off, 1.on):
1
GSM signal report(0.off 1.1days 2.7days 3.15days
4.30days):
0
Balance checking alerts (0.off 1.1day 2.7days
3.15days 4.30days):
0
3. Forward and edit the SMS
You will receive several messages separately. You can forward one of the them and
edit it.
For example, if you want to set timed arm/disarm:
Entrance delay time(5-299s):
5
Timed arm/disarm(0.off 1.on,00:00 0 - 00:00 0):
07:30 1-11:30 0
Note:
Set Auto-Arm Time
Set Auto-Disarm Time
07:30
1
11:30
0
You can choose on or off by typing 0 or 1
EN
18