MINIMUM MANTEL CLEARANCES
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
Combustible mantel clearance can vary according to the mantel depth. Use
the graph to help evaluate the clearance needed. These same requirements
apply to any combustibles protruding on either side of the appliance. The
minimum distance, from the bottom of a combustible mantel projecting 3"
(76mm) maximum from the wall to the top of the aluminum trim, is 3" (76mm).
WARNING
!
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
7" (178mm)
6" (152mm)
5" (127mm)
4" (102mm)
3" (76mm)
2" (51mm)
1" (25mm)
0
1
2 3 4 5 6 7
MANTEL WIDTH
73.1
6" (152mm) MANTEL
A = 6" (152mm)
B
B = 5" (127mm)
C
C = 4" (102mm)
A
D
D = 3" (76mm)
B
C
D
W415-1404 / 10.15.14