Minimum Combustible Mantel Clearances; Non-Combustible Facing Material; Side View; Top View - Continental Fireplaces CHD35NT Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.4

MINIMUM COMBUSTIBLE MANTEL CLEARANCES

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed.
MANTEL DIMENSIONS
Ref
38" (965mm)
A
13" (330mm)
B
15" (381mm)
C
17" (432mm)
D
19" (483mm)
E
F
A
2" 51mm
4" 102mm
5.5

NON-COMBUSTIBLE FACING MATERIAL

SIDE VIEW

FINISH
MATERIAL
FRONT OF
APPLIANCE
WARNING: Non-combustible facing material must not protrude more than 3/4" (19mm) from the top,
WARNING: for non-combustible facing material that protrudes more than 3/4" (19mm) from the top, and/or sides of the
appliance, refer to the diagram.
and/or sides of the appliance. If it does, it is considered a non-combustible mantel and must meet the
non-combustible mantel clearance requirements.
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
Height
Depth
2" (51mm)
4" (102mm)
6" (152mm)
8" (203mm)
21
INSIDE
19
CHASE
17
2" 51mm
15
4" 102mm
13
11
6" 152mm
NON-COMBUSTIBLE
FACING MATERIAL
3/4" (19mm)
WARNING
!
2
4
6
8 10
MANTEL DEPTH
FRONT OF
APPLIANCE
3/4" (19mm)
73.1
E
D
C
B
A
TOP VIEW
FINISH
MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
71.3A
W415-1348 / A / 07.17.15
33
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Chd40ntChd46ntChd35ptChd40ptChd46pt