Remedy Of Faults; Wear Parts; Maintenance And Cleaning - Pontec PondoClear Set Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20

Remedy of faults

Malfunction
The unit performance is not satisfactory
UVC lamp display is not lit
No water outlet from the pond inlet

Wear parts

· Foam filter
· Impeller unit
· UVC lamp, quartz glass and O ring for quartz glass

Maintenance and cleaning

Carry out the cleaning and servicing measures described in the following at regular intervals in order to ensure proper
function of the individual units. The cleaning cycle depends on the degree of soiling/pollution of the garden pond. Fol-
low the warning and safety information!
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
· Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
· Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleanfilter
Prior to starting cleaning and servicing of both filter and submersion unit, switch the submersion unit off and open the
unit in question (® Installation). When finished, thoroughly close the units again and check all connections and lines
for perfect function.
How to proceed:
5 F
1. Pull out all foam filter at the same time.
2. Remove all bio balls
3. Rinse foam filters, container and bio balls under running water.
4. Reinsert the foam filters into the container at the same time.
– Ensure that the foam filters are correctly arranged and aligned!
5. Return the bio balls to the chamber on the outlet side.
6. Close the container. (® Installation)
Replace the different filters
· Replace old filters by new filters. The procedure is identical to that described for filter cleaning. (® Cleaning filters)
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
Pump filter housing soiled
Impeller unit blocked
Quartz glass tube soiled
UVC lamp capacity exhausted
Power supply of UVC not connected
UVC lamp defective
Connection defective
UVC overheated
Pump power supply not connected
Pond inlet blocked
Remedy
The complete biological cleaning effect is only
achieved after several weeks
Remove algae and leaves from the pond, per-
form a partial water change
Guide value: approx. 60 cm fish length in 1 m³
pond water
Clean filters
Clean pump filter housing
Clean pump
Remove UVC and clean quartz glass
Replace the lamp after approx. 8000 operating
hours
Connect UVC power plug
Replacing the UVC lamp
Check electrical connection
UVC automatically switches on when cooled
down
Connect pump power supply
Clean pond inlet
- EN -
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4000

Table des Matières