USING THE RANGETOP

BURNER CONTROL KNOBS
Each sealed burner has its own control knob. The symbol below each knob indicates which burner is
controlled by each knob. Push and turn LEFT (counter-clockwise) to HI to ignite the flame, then turn
EN
to the desired flame setting.
BURNER TYPES & OUTPUT
This table indicates the
type and output of each
sealed burner. Dual-flow
burners have an inner and
outer row of ports, with
a simmer function. The
single-flow burner (some
models) is similar to a
commercial burner and
features very high output,
and a low, but no simmer
function.
RE-IGNITION
Each sealed burner has its own electronic spark-ignition module with flame-sensing technology and
automatic re-ignition capability. If any burner should blow out, the igniter automatically re-lights the
burner.
Each burner should light in less than 4 seconds. Once lit, the sparking will stop. On very low simmer,
an occasional sparking may occur. This is usually due to a breeze in the room. If an igniter continues
to spark even with a flame present, there could be an electrical wiring issue, or some other problem.
See the TROUBLESHOOTING section of this manual for more information.
DO NOT touch the burner or the igniters while sparking is occuring. A shock hazard or burns could
occur.
MANUAL LIGHTING / POWER FAILURE
THE GRIDDLE CANNOT BE USED DURING A POWER FAILURE.
Each sealed burner can be manually lit in the event of a power failure. It is necessary to light each
burner individually.
If a power failure occurs WHILE you are using the sealed burners, turn all the knobs to the OFF
position - then light manually with a match or fireplace lighter.
Position the match or fireplace lighter at the port nearest the igniter, then turn the knob to HI until
the flame is lit. Wait until the flame has lit all the way around the burner before adjusting the knob
to LOW or SIMMER.
IF YOU SMELL GAS, turn all control knobs to OFF - check the precautions listed in the SAFETY
section of this manual.
14
©2019 Hestan Commercial Corporation
BURNER OUTPUT - NATURAL GAS
DUAL-FLOW
OUTPUT
DUAL-FLOW
(FRONT)
(BTU/hr)
23000
HI
LOW
4200
SIMMER HI
1500
500
SIMMER LOW
SIMMER LOW
BURNER OUTPUT - PROPANE
DUAL-FLOW
OUTPUT
DUAL-FLOW
(FRONT)
(BTU/hr)
23000
HI
4200
LOW
SIMMER HI
1500
SIMMER LOW
600
SIMMER LOW
OUTPUT
(REAR)
(BTU/hr)
15500
HI
LOW
4200
SIMMER HI
1500
500
OUTPUT
(REAR)
(BTU/hr)
15500
HI
4200
LOW
SIMMER HI
1500
600
SINGLE
OUTPUT
FLOW
(BTU/hr)
30000
MAX
LOW
4200
SINGLE
OUTPUT
FLOW
(BTU/hr)
22000
MAX
LOW
4200