Loading the feed screw.
Should the pellet hopper empty completely the feed screw
must be fi lled. To do so, keep the + and – keys pressed simul-
taneously for a few seconds (on the remote control or synoptic
panel). Once released, 'REFILL' will appear on the display.
This must be carried out before ignition if the stove has stopped
due to the pellets having fi nished.
It is quite normal for some pellet residue to remain inside the
hopper, this is what the feed screw is unable to pick up.
Once a month, fully vacuum the hopper to prevent dusty resi-
due from accumulating.
Automatic ignition
With the stove on standby, press the 0/1 button for 2 seconds
(on the synoptic panel or remote control). This will startup
the ignition process, 'Start' will appear on the display and a
countdown will commence in seconds (1020). There is no
preset time for the ignition process: its duration will be automa-
tically shortened if the control board detects that certain tests
have been carried out positively. The fl ame appears after about
5 minutes.
Manual ignition
At a temperature lower than 3 °C – too low for the electrical
resistance to become red hot - or if the resistance is temporarily
not working, you can use a fi relighter to ignite the stove.
Insert a well-lit fi relighter into the combustion chamber, close
the door and press 0/1 on the synoptic panel or remote control.
Operating modes
Manual: the user sets the desired operating power (from
a minimum of 1 to a maximum of 5)
Automatic: the user sets the temperature desired in the
room. The stove reads this and adjusts the power to reach
the set temperature. Once this is reached, it sets itself to
power 1.
Manual mode from synoptic panel/remote control
(optional)
With the stove in operation mode or on standby, press and
release the MENU button on the synoptic panel/remote
control and 'Power' will appear on the display (showing
the power at which the stove is working). Rotate the left
knob or press the + key on the remote control to increase
the operating power (from Power 1 to Power 5).
Setting the fan via the Synoptic Panel
With the stove in operation mode or on standby, rotate the
right knob to adjust the ventilation setting (from 1 to 10 in
all powers).
Automatic mode from synoptic panel/remote control
(optional)
Press the MENU button twice to switch from manual to
automatic mode and adjust the temperature desired for the
room (use the right knob on the panel or the + and – keys
on the remote control to set the temperature between 10
and 29 ...., and the stove will regulate the operating power
required to reach it.
If the set temperature is lower than the room temperature,
the stove works at Power 1.
INSTRUCTIONS FOR USE
- 29
Shutdown
For greater comfort, the stove and the air vents go off
at the same power at which it was operating.
With the stove in operation mode press the 0/1 key for 2
seconds (on the synoptic panel or remote control). The
shutdown procedure will begin and the countdown is
displayed. This varies according to the power at which it
is running when the shutdown phase begins.
The shutdown phase (which will extinguish the fl ame
without leaving any unburnt material in the combustion
chamber and cool the stove), consists of:
• Pellet loading ceases.
• Ventilation is activated at the level at which the stove
was operating.
• Smoke expulsion motor enabled.
Never unplug the stove during the shutdown process.
Setting the clock
Press the MENU button for 2 seconds and use the + and –
keys to follow the instructions given on the display to
access the 'Clock' menu. This allows you to set the time on the
electronic control board.
Then press MENU and the following data appears in
sequence – this can be adjusted:
day, month, year, hour, minutes, day of the week.
When 'Save?' appears on the display you can check that
the settings have been entered correctly before confi rming.
Press MENU to save the information ('Save OK' then
appears on the display).
Weekly timer
Press the MENU button on the remote control for 2
seconds to access the time setting function and press the
+ key to access the weekly timer function – 'Program ON/
OFF' will appear on the display.
A maximum of three timer programs can be set for each
day of the week.
As you confi rm via the MENU button, one of the following
options will appear:
- 'No Prog.' (no program is set).
- 'Daily program' (a single program is set for every day)
- 'Weekly program' (a program is set for each day of the
week).
Move from one to the other using the + and – keys.
Use the MENU button to confi rm the 'Daily program'
option and access the selection of the number of programs
(ignition/shutdown) to be set per day. Use the 'Daily program'
option to set the identical program/s for every day
of the week.
The following will be displayed if the + key is pressed:
- No Programs.
- 1st daily program (one ignition and one shutdown per
day), 2nd daily program (same as before), 3rd daily program
(same as before).
Use the MENU button to show them in reverse order.
If the 1st program is selected, the ignition time is shown.
The display shows: 1 Ignition Hour 10.30; use the +/–
keys to change the hour and press MENU to confi rm.
The display shows: 1 Ignition Minutes 10.30; use the +/–
keys to change the minutes and press MENU to confi rm.
-