Installation sequence
2.3 Installing the hopper
– Together with the auger conveyor, insert the hopper into the auger tube (Fig. 10) and hook into the 2 hooks, marked
yellow – Fig. 11.
– Tighten the fastening screws at the top as securely as possible (as marked) – Fig. 12.
– Secure the container at the bottom, next to the auger tube, with an M8x16 hexagon screw (provided in plastic bag
attached to container) – Fig. 13.
– Remove cover from hopper by loosening the 3 screws on each side and removing the cover – Fig. 14.
Fig. 10
Insert auger conveyor into bottom of
auger tube
Fig. 12
Tighten fastening at top as rmly as pos-
sible (as marked)
Fig. 14
Loosen the 3 screws on each side and
take o cover.
Fig. 11
Suspend hopper from 2 hooks, as
marked
Fig. 13
Tighten screws at base of hopper
17