3 Product description

3.1 General information

AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisa-
tion and Restriction of Chemicals.
Neither refrigerant R-290 nor the blowing agent pen-
tane have an ozone depletion potential (ODP).
R-290 has a very low global warming potential (GWP)
of 3.

3.2 Technical data

Key technical data can be found on the rating plate
(see →Rating plate and serial number).
Parameter
See →Appliance model over-
External dimen-
sions
view
See →Appliance model over-
Appliance weight
view
Airborne noise
emitted/emission
< 70 dB(A)
sound pressure
level
Refrigerant
Propane (R-290)
Series
Area of
Adjusta-
use/ op-
ble lev-
erating
mode
Impulse
Standard
ice cream
Electrical connection
Parameter
Rated voltage/ rated
220 - 240 V/50 Hz
frequency
Connecting cable
3-pin cable
Minimum cross-sec-
tion for connecting
0.75 mm
cables
Plug types
CEE 7/7
Plug types
BS 1363
Fusing
See →Fusing
Rated
Fault
current
current
[A]
[mA]
Circuit breaker (LS/CB)
16
-
Residual current circuit breaker (FI/RCCB/GFCI)
G (short-time delay)
A (pulse current-sensi-
tive)/
40
30
F (mixed frequency-sen-
sitive)/
B (universal current-sen-
sitive)
405862_1_0819
Value
Equivalent to the
control range for in-
els
door temperature
1 - 7
-14°C ... -23°C
Value
2
Type
Tripping
charac-
teristic
C (slow-
-
acting)
-
Rated
Fault
current
current
[A]
[mA]
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
G (short-time delay)
A (pulse current-sensi-
tive)/
16
30
F (mixed frequency-sen-
sitive)/
B (universal current-sen-
sitive)
Custom deviations possible.
More information: Maintenance service (see →Mainte-
nance services).

3.2.1 Rating plate and serial number

Observe the information on the rating plate.
The rating plate is a sticker on the back of the appli-
ance.

Information on rating plate

Appliance name and type
Serial number
Climate class*
Rated voltage and frequency
Rate current and consumption
Refrigerant and quantity used
Net content
Date of manufacture
and further technical data
*Examples of climate classes:
Climate class
Ambient tem-
pursuant to ISO
perature [°C]
23953-2
7

4 Use as intended

The appliance is intended for the display of packaged,
deep frozen food products, in particular ice cream, or
access to them by customers. For more information,
see →Use as intended
Product description | 3
Type
Tripping
charac-
teristic
C (slow-
acting)
Relative humid-
ity [%]
35
75
29 / 436