Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
agents, alcohol, acetone or solvents; Do not use detergent containing nonionic surfac-
tants, lemon o vinegar (acetic acid). NEVER CLEAN THE DISPLAY CASE BY THE USE OF WATER
JETS (fig. 16). Clean glass surfaces using glass-cleaning products only. The use of water is not
recommended here, as it may cause scale to build up.
2) Every month clean the cabinet inside surfaces following the instructions provided in the prece-
ding item, only using a non-abrasive sponge (the maximum temperature of the usable water for
the cleaning is of 65°C) and those indicated here below:
• Disconnect the cabinet from the power mains using the wall main cutoff switch (fig. 18).
Those who carry out the maintenance work must constantly ensure that the cabinet is
not powered up again by other personnel.
• Empty the appliance, store its contents in coldrooms or refrigerators that are adequate for kee-
ping the requisite preservation temperature.
• Wait until the showcase has reached ambient temperature and then clean according to the above
instructions. The incorporated drain facilitates the collection of wash water by conveying it directly
outside the cabinet.
• After having carefully checked that the cabinet is completely dry, reassemble it and switch it on.
• Allow a couple of hours before loading the products back again.
To clean the base deck it is also possible to turn the fan holder upwards.
3) Once a year, clean the condenser with a hard non-metal brush removing removing dust and dirt
from between the fins. To access the condenser, it is necessary to disconnect
the appliance from the power mains and then remove the appropriate rear guard detaching it from
the magnets (see fig. 21 on page 24). A dirty condenser cools imperfectly, so causing waste of
energy and poor performance. Wear heavy-duty gloves when cleaning the condenser.
4) Defrost the showcase every three months to let the ice that may have formed between the eva-
porator fins melt, since frost may otherwise prevent correct operation. Proceed according to the
instructions for cleaning the inside surfaces at item 2, but allow a longer wait time for the ice to
melt completely.
Any maintenance operation not dealt with above, must be carried out by the authorised after-sales
service or by qualified personnel.
11. EMERGENCY SITUATIONS
1) The cabinet will not start or will not keep on working:
• there may be a general blackout;
• the wall main switch may be off;
• the plug of the appliance may be out of the socket.
If power failure is not due to any of the above causes, call the nearest after-sales service
immediately, empty the showcase and store the foods in coldrooms or refrigerators that
may ensure their preservation temperature.
2) The showcase will not cool properly
• the condenser may be dirty and therefore unable to exchange heat. If it is obstructed with dust
or dirt, clean thoroughly as explained in section 10;
• make sure that the product load is correct (see section 7);
• if the showcase has not been defrosted for longer than 3 months, defrost and clean it before
starting normal operation (see section 10, item 4);
• make sure that the case is not exposed to sources of heat or draught;
• make certain that ambient conditions comply with the requirements of page 18, table II;