4) Every six months clean the honeycomb , in the following way (fig. 16 - pag. 7)
a) Loosen the screws fixing the support;
b) remove the honeycomb;
c) use a jet of hot water (max. 70°C) to remove any dust which may have accumulated on the honeycomb;
d) dry with a jet of air;
e) replace the honeycomb with great care.
Disassemble a a nd a a ssemble v v ery s s lowly, u u sing w w ork g g loves. I I t i i s a a dvisable t t o h h ave t t hese c c leaning o o pe-
rations c c arried o o ut b b y a a uthorized s s ervice p p ersonnel.
Any maintenance operation not included among the former steps must be carried out by the authorised after-
sales service or by qualified personnel.
CANOPY LIGHTING: canopy lamps must be replaced by the after-sales service only. Resort to it if need be.
11. EMERGENCY SITUATIONS
1) The d d isplay c c ase w w ill n n ot s s tart o o r w w ill n n ot k k eep o o n w w orking:
• There may be a general black-out;
• The wall main switch may be off.
If p p ower f f ailure i i s n n ot d d ue t t o a a ny o o f t t he a a bove c c auses, c c all t t he n n earest a a fter-s s ales s s ervice i i mmediately,
empty t t he d d isplay c c ase a a nd s s tore t t he f f oods i i n c c oldrooms o o r r r efrigerators t t hat m m ay e e nsure p p reservation
temperature.
2) The d d isplay c c ase w w ill n n ot c c ool p p roperly
• Make sure that the product load is correct and the air slots are not covered;
• defrost and clean it before starting normal operation (see chapter 10);
• Make sure that the case is not exposed to sources of heat or draught;
• Check that the display case is perfectly horizontal by the use of a spirit level. Make certain that ambient conditions
comply with the requirements of page 4.
Should insufficient cooling persist, resort to the nearest after-sales service.
3) The c c abinet o o perates n n oisily:
• Make sure that screws and bolts are closed tight.
• Check that the display case is perfectly horizontal by the use of a spirit level.
IN CASE OF A GAS LEAK OR FIRE, do not breathe inside the room that houses the display case before
having aired it properly. Turn the display case off by the main switch ahead (see fig. 17). DO NOT USE
WATER BUT ONLY DRY EXTINGUISHERS TO EXTINGUISH THE FIRE.
12. AFTER-SALES SERVICE
Should it be necessary to resort to technical assistance, contact your sales person immediately. If spare parts are