5 INSTALLATION SITE
PREPARATION
5.1 GENERAL INFORMATION
The following paragraphs provide instructions that
must be complied with in order to ensure maximum
efficiency of the product purchased and safe
operation.
The following instructions are however subordinate
to compliance with any national, regional and local
laws and standards in force in the country where
the product is installed.
5.2 SAFETY PRECAUTIONS
Responsibility for work carried out in the place
where the boiler is installed lies with the user;
the user is also responsible for making sure the
installation checks are completed.
The user must abide by all local, national and
European safety requirements.
suitable load-bearing capacity.
The boiler assembly and dismantling instructions
are reserved exclusively for specialist technicians.
Users should always contact our service centre
to request work to be performed by qualified
technicians.
Before having work performed by other technical
personnel verify their effective technical
competence. Before starting to assemble or
dismantle the boiler, the installer must heed the
A) do not work in adverse conditions;
B)
working and make sure that personal protective
equipment is in perfectly working order;
C) always wear safety gloves;
D) always wear safety shoes;
E) always use electrically insulated tools;
F) make sure that the area being used for
assembly and dismantling is clear of any
obstacles.
38
INSTALLATION
5.3 BOILER INSTALLATION SITE
Fig. 5.1 and the corresponding table show the
in centimetres that must be observed when
positioning the boiler, to ensure safety and access
for maintenance;
A)
B) Rear wall.
C) Side wall.
D)
gas attachment.
wood, parquet, linoleum, laminates or carpets
base underneath boiler. Such base may be made
from steel, slate, glass or stone and must cover the
attachment, and must extend at least 50 cm at the
front.
The manufacturer declines all liability for any
alterations to the characteristics of the material
Any elements made from wood (e.g. beams) or
other combustible material located near the boiler
Flammable walls or elements must be kept at least
80 cm away from the boiler.
a
b
c
d
cm
60
60
60
100
Fig. 5.1