System Settings
ITEM
NIMH SENSITIVITY
A
D. PEAK
4MV
NICD SENSITIVITY
A
D. PEAK
4MV
KEY BEEP
ON
A
BUZZER
ON
DC INPUT LOW:
A
CUT-OFF
11.0V
LOAD FACTORY SET
A
ENTER
VERSION
A
HW: 1.00 SW: 1.00
SELECTION
Default: 4mV/Cell
3-15mV/Cell
This program allows you to select whether or
not the RDX2 Pro beeps when you push buttons,
OFF/ ON
and if the buzzer sounds to alert you when a
charge/discharge operation is complete.
This program monitors the voltage of input
battery. If the voltage drops below the value you
10.0-12.0V
set the operation is forcibly terminated to protect
the input battery.
Press and hold ENTER for 3 seconds to load
factory default settings.
It indicates the hardware and firmware version.
DESCRIPTION
This program is for NiMH/NiCd battery only.
When the charger detects the delta peak
value reaches the value you set, the charger
will say the battery is fully charged.
29