HITEC RDX2 Pro Notice D'utilisation page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating the Charger
Charging Status Monitor: Once the charge process is started, the real-
time status will be shown which includes: Cell Count, Amperage, Voltage,
Timer, mAh of Charged Capacity. SCROLL to view a variety of other useful
information. Scrolling counterclockwise will display the FUEL=% & Cell
Voltage.
This shows how full the pack is from 0% - 100% and the Average Cell
voltage. Continue scrolling to show each individual cell voltage. This is
helpful in determining how well balanced the pack is.
These should be no more than .02v from each other. A significant disparity
is a sign that there are one or more bad cells.
Further scrolling will show the settings for:
Capacity CUT-OFF
Safety Timer
Internal Temperature of the Charger
Input Power Voltage
End Voltage
Charge Process Complete: Once the battery is fully charged,
the screen will read "END: FINISH" and the charger will emit
an audible "ring" sound. Battery voltage, mAh capacity and
elapsed time will be displayed.
Program Stop: You can press the MODE/STOP at any time
throughout the charge or discharge process to stop the
16
process.
LP3s 2.0A 12.14V
A
BAL 000:50 00022
FUEL = 90%
A
Cell = 4.07V
4.07 4.06 4.07 V
A
0.00 0.00 0.00 V
CAPACITY CUT-OFF
A
ON 5000MAH
SAFETY TIMER
A
ON 120 MIN
Int. Temp 94
A
IN POWER VOLTAGE
A
15.8V
END VOLTAGE
A
12.60V (3S)
[END FINISH]
A
12.60V 2000mAh
A [TIME: 00:45:32]
12.60V 2000mAh
0
F

Publicité

Table des Matières
loading