SC24
9 - DIP SWITCH SW4
The settings are stored during the rest phase (gate closed
The DEFAULT settings are coloured in grey .
DIP
Function
ATTEMPTS AFTER
DIP1
SAFETY DEVICES
INTERVENTION
--
DIP2
10 - TRIMMER ADJUSTMENT
Trimmer
Default
PAUSE
AMP.
SLOW
SLOW
AMP.
FORCE
FORCE
Status
Description
ON
Disables the function.
Enables the function attempts after the intervention of the safety devices.
After the intervention of the safety device SAFETY or SAFETY-STOP
(DIP 10 = ON) or of the ANTI CRUSHING and, after 10 seconds, the automation
will try, for 3 times max., to restart the motion in the direction that has been
interrupted.
After another intervention of the safety device, the automation stops waiting for
some commands.
OFF
A programming of the function different from the configuration pre-set by the
manufacturer, although it allows, if correctly done, the reduction of the cases
of stop of the system in intermediate position (as a simply example, for the
presence of frictions, wind and/or obstacles on the way of the movable element),
causes, in any case, a reduction of the safety level of the same system and a
consequent danger for people safety.
ON
OFF
Description
Adjusts the PAUSE TIME from 2 to 225 seconds.
The value is increased by turning the trimmer clockwise.
Adjusts the intervention sensitivity of the anti crushing during the decelerated movement
period.
Turning the trimmer clockwise, the sensitivity decreases.
Adjusts the motor FORCE/SPEED during the decelerated movement period.
Adjusts the intervention sensitivity of the anti crushing during the not decelerated movement
period.
Turning the trimmer clockwise, the sensitivity decreases.
Adjusts the motor FORCE/SPEED during the decelerated movement period.
).
WARNING!
--
--
15
UK