Technical Characteristics; Control Unit - GiBiDi SC24 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
10
UK

1 - TECHNICAL CHARACTERISTICS

Control unit

Type
Power supply
No. of motors
Motor power supply
Flashlight
Warning light
Accessory and safety device
power supply
Radio-receiver
Operating temperature
Run time
Pause time
Recommended battery type
Soft start
2 - TECHNICAL CHARACTERISTICS / FUNCTIONS
Red warning leds of N.C. (photocell, closing limit switch, opening limit switch) and 8K2 contacts (safety device, stop
Green warning leds of N.O. contacts (start and ped
START and PED buttons on board
Safety test run before the opening and closing movement
Deceleration during opening and closing controlled by 2 additional magnets
Stop and motion inversion for 1s after the intervention of safety devices. At next Start pulse the motion restarts in
the obstacle freeing direction
Amperometric reading of motor absorption for the anti-crushing function both during normal operation and in slow
motion. (adjustable with AMP.FORCE and AMP.SLOW trimmers). The amperometric intervention determines
stopping and motion inversion for 1 second. At the next Start pulse the motion restarts in the obstacle freeing
direction
.
Automatic closing and Pause time programming
Pedestrian operation with fixed opening of 10 s. Pedestrian operation works with automatic logic
Provision for use with buffer batteries (accessory battery charger board, code AJ00601
Test of battery charge status. During battery operation, an acoustic signal synchronised with the flashlight will be
activated. When the batteries are nearly flat and an opening command is given, the gate will open and remain thus.
Should the batteries not be sufficiently charged, the gate will not open
Photocells active during closing or during closing and opening selectable by dip switch
• R
Force and Slow down adjustable by trimmers (FORCE, SLOW
Operating logics: Automatic - Step by Step, Step by Step with Stop, Dead Man
Energy saving function
Soft Start and soft-Stop to avoid mechanical shocks
1 input for 8K2 safety device
1 input selectable as 8K2 safety device or STOP 8K2
Electronic control unit for automation of a sliding gate
.
.
.
.
SC24 / AS05700
with 24 Vdc motor
230 Vac
single-phase
24 Vdc
24 Vdc 10W max
24 Vdc 3W max
24 Vdc 8W max total
Pluggable radio receiver
-20°C +60°C
240 sec. fixed
Adjustable between 2 and 250 sec.
Rechargeable lead battery 24V 2Ah (2 x 12V 2Ah)
1 sec.
).
.
.
.
).
.
.
50/60 Hz
1
.
.
).
.
.
SC24
).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

As05690As05700

Table des Matières