T Rouble Shooting - Gaggenau AC250121 Notice D'utilisation

Masquer les pouces Voir aussi pour AC250121:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Trouble shooting
en

T rouble shooting

3
M alfunctions often have simple explanations. Please
T r o u b l e s h o o t i n g
read the following notes before calling the after-sales
service.
m
Warning: Risk of electric shock!
Incorrect repairs are dangerous. Repairs may only be
carried out and damaged power cables replaced by one
of our trained after-sales technicians. If the appliance is
defective, unplug the appliance from the mains or switch
off the circuit breaker in the fuse box. Contact the after-
sales service.
Fault
The appliance does not work
The remote control is not working
After the appliance has been switched
off, the LEDs 1-5 flash three times.
LED 1 or LED 2 flashes in the display
--------
42
Possible cause
The plug is not plugged into the mains
Power cut
The fuse is faulty
The battery is flat
The battery is nearly flat
The metal grease filter or the activated
charcoal filter is saturated.
Solution
Connect the appliance to the power
supply
Check whether other kitchen appliances
are working
Check in the fuse box to make sure that
the fuse for the appliance is in working
order
Change the batteries in the remote con-
"Replacing the
trol, see section ~
batteries in the remote control"
on page 41
Change the batteries in the remote con-
"Replacing the
trol, see section ~
batteries in the remote control"
on page 41
Clean the metal grease filter or replace
the activated charcoal filter.
"Cleaning and maintenance"
~
on page 39

Publicité

Table des Matières
loading