The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
EN
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location
for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
Maximum Input
Maximum Output
Effi ciency
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation. The natural gas model can only be installed in a mobile home that is permanently positioned
on its site and fueled with natural gas. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance or purchased as a mandatory front shall be installed.
W415-1367 / 12.05.14
www.nficertified.org

RATES AND EFFICIENCIES

NATURAL GAS
4.5" (11mb) Water Column
7" (17mb) Water Column
3.5" (9mb) Water Column
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
4.1B
PROPANE GAS
6,000
4,680
78%
11" (27mb) Water Column
13" (32mb) Water Column
10" (25mb) Water Column
6,000
4,680
78%