Télécharger Imprimer la page

Electrical Connections - Nilfisk IQ 215 Mode D'emploi

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9

ELECTRICAL CONNECTIONS

DOUBLE-INSULATED MACHINES
Your MACHINE must only be connected to an
electrical supply of the same voltage and frequen-
cy as indicated on the rating plate. Ensure that the
plug fitted to the end of the power supply cord is
suitable for your supply socket, if not refer to the
information contained in 'Electrical Connections',
or consult a qualified electrician. The electrical
installation from which the supply is drawn must
be maintained to current Institute of Electrical
Engineers wiring regulations.
IMPORTANT
240 volt 50 Hz. machines are fitted with a 13 amp.
3 pin moulded plug. the plug is fitted with a 10 amp.
detachable fuse. The correct replacement for the
fuse is identified by marking or colour coding.
Only fuses that are ASTA approved to BS 1362
should be fitted. Never use the plug without the
fuse cover fitted. Replacement fuse covers are
available at any electrical retail outlet.
If the available socket outlet is not suitable for the
plug supplied, the plug must be cut off and an
appropriate plug fitted. The plug thus cut off
MUST BE DESTROYED for safety reasons before
being disposed of.
Machines built for other voltages and frequencies
are not normally supplied with a fitted plug.
If it is necessary to fit a plug, the wires in this
power supply cord are coloured in accordance
with the following code:
BLUE-NEUTRAL
BROWN-LIVE
(Only applicable to UK)
To connect the new plug:
If using a three-pin plug, do not make any connec-
tion to the the terminal in the plug which is
marked with the letter 'E' or by the safety earth
symbol or coloured green or green & yellow.
This machine is double-insulated and no earth
connection is necessary.
The wire which is coloured blue must be connec-
ted to the terminal in the plug which is marked
with the letter 'N' or is coloured black or blue.
The wire which is coloured brown must be
connected to the terminal in the plug which is
marked with the letter 'L' or is coloured red or
brown.
If the plug to be fitted does not conform to the
above notation then consult a qualified electrici-
an.
9

Publicité

loading