SinePower
11
Troubleshooting
!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
The LED (fig. 2 2) indicates the fault:
LED display
Cause
Quick flash
Input voltage is
too high
Input voltage too
low
2 s lit, short
Overheating
interruption
Excessive load
Off
Other fault
EN
Remedy
Check the input voltage and reduce it.
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the consumer.
Wait 5 to 10 minutes and switch the inverter on again
without any electric consumers.
Reduce the load and make sure the inverter has better
ventilation. Then switch the consumer back on.
Switch off the inverter and remove the consumer.
Then switch the inverter back on without the con-
sumer. If no excessive load is now shown, then there
is a short circuit in the consumer or the total load was
higher than the power specified on the data sheet.
Check the cables and connections.
Contact the service.
Troubleshooting